- Contact Person : Ms. Chen Iry
- Company Name : Wuxi Jinyibo Instrument Technology Co., Ltd.
- Tel : 86-510-83217963
- Fax : 86-510-83217963
- Address : Jiangsu,Wuxi,No.35 Jingshen Rd, Qianqiao Development Zone
- Country/Region : China
- Zip : 214151
TY-9610 Type Direct Reading Spectrometer
Main technical parameters:
Test Matrix (Multi-matrix) | Analysis Fe,Al ,Cu, Ni ,Co ,Mg, Ti, Zn, Pb, Sn ,Ag etc. and their alloys samples |
Analysis passageway (Multi-passageway) | 45 passageways |
Analysis of band (wide rande) | 120~850nm |
Detection time(short time) | Depend on different type of sample, generally less than 30s |
Optical chamber(finishing temperature) | 38°C±0.2°C |
Power supply | Protect grounding single-phase power supply. Voltage:220VAC; Frequency:50Hz; Use of power:1.8KVA |
Environment conditions | Working tenperature:10-30°C; Shorage temperature:0-45°C; Humitidy:equal to or less than 85% |
The key characteristics:
1.750mm focal length grating design, Palmer-Rungedevice, high vacuum, high resolution and high sensitivity.
2.Electronic system adopts international standard cage and integrated circuit design.
3.The frequency of excitation light source is adjustable between 150 and 600Hz. Analysis different samples; choose different excitation parameters, to achieve the best analysis result.
4.Excitation light source adopts solidity auxiliary electrode to solve the interference issue and improve the stability of excitation light source. It doesn’t need to be adjusted.
5.Channel negative high voltage are divided into 8 levels to adjust itself, thereby greatly improving the utilization of and analysis of passageway and analysis the best linearity range of spectral line in different material so as to reduce the use amount of passageway and the cost.
6.Optica’s integral constant temperature measures ensures the proper operation of the instrument, thereby reducing the demands on the environment.
10.The vacuum chamber is made of aluminum alloy, molding once.
11.Aseismatic design of spectrum room, some important optical elements like gratings, slit etc. is installed dynamicallyso as to can get high optics stability.
12.Install fatigue lamp in the spectrum room improves the stability of photomultiplier, eliminates the dead time of photomultiplier, enhances the SNR (Signal to Noise Ratio) and extends the service life.
TY-9610 Type Direct Reading Spectrometer